Ó¡Ë¢µç·°å¼ÌµçÆ÷

  • OA 5681
... more

²ÎÊý

Contact equipping: 1
Continuous current: 16 A
Nominal voltage: DC 6 - 110 V
Voltage Range UN: 0,7 - 2,2
Protection type: RT II (flux-proof relay)
Size L x W x H: 29 x 25 x 12,5 mm
Test voltage (AC) contact set - coil: ¡Ý 4 kV eff
Type of relay: Monostable
Temperature range (- / +): -40 - 110 ¡ãC
Contact material: AgSnO2, AgNi
Clearance and creepage distances, contact set - coil ¡Ý: 8 mm
Relay type: OA 5681

ÓÅÊÆ

ÌØÕ÷

  • According to DIN EN 61810-1, DIN EN 60664-1
  • Clearance and creepage distances: contact-coil ¡Ý 8 mm
  • Compact size, small height (at horizontal model)
  • OA 5671 / 5681 horizontal mounting
  • OA 5672 / 5682 vertical mounting
  • OA 5671 and OA 5672 for continuous currents to 10 A or with contact with 5 ¦Ìm Au
  • OA 5681 and OA 5682 for continuous currents to 16 A
  • OA 5672 as option with 7 mm or 10 mm pin distance
  • For continuous operating temperature to 110¡ãC
  • Voltage range 0.7 UN ... 2.2 UN
  • Solder line proof