... more
²ÎÊý
| Contact equipping: | 4 |
| Continuous current: | 3 x 8 A |
| Nominal voltage: | DC 6 - 110 V |
| Voltage Range UN: | 0,7 - 1,4 |
| Protection type: | RT II (flux-proof relay), optional RT III (wash-tight) |
| Size L x W x H: | 41,9 x 14,5 x 30,5 mm |
| Test voltage (AC) contact set - coil: | ¡Ý 4 kV eff |
| Type of relay: | Monostable |
| Temperature range (- / +): | -40 - 85 ¡ãC |
| Type acc. to DIN EN 61810-3: | A |
| Approvals: | TÜV |
| Contact material: | AgSnO2, AgNi |
| Clearance and creepage distances, contact set - coil ¡Ý: | 8 mm |
| Relay type: | OA 5611 |
ÓÅÊÆ
ÌØÕ÷
- According to DIN EN 61810-1, DIN EN 61810-3 (Type A)
- With forcibly guided contacts
- High switching reliability due to crown contacts
- Low rated power consumption
- High mechanical service life
- High temperature range - 40 ... + 85¡ãC
- High continiuous thermal current Ith = 8 A
- Compact size
- Optionally wash proof