²Ëµ¥
ËÑË÷
Search
·þÎñÇøÓò
¹Ø±Õ²Ëµ¥
·þÎñÇøÓò
怫
²úÆ·
ÐÐÒµ
Ó¦ÓÃÁìÓò
¹ØÓÚÎÒÃÇ
·ÖÀà²úÆ·
²úÆ·²éѯ
¼ÌµçÆ÷Ä£¿é
°²È«¼¼Êõ
¼à¿ØÄ£¿é
µçÁ¦µç×Ó
¿ØÖÆÉ豸
¶¨Ê±Æ÷
°²×°µç×ÓÉ豸
°²È«¿ª¹Ø£¬·À»¤Ëø£¬Ô¿³×½»»»
°²È«¿ª¹Ø
·À»¤Ëø
Ô¿³×½»»»
µ¥¸öÄ£¿é
Ö¸ÁîÉ豸
´øÁªËøµÄ¸ºÔظôÀëÆ÷
PCB ¼ÌµçÆ÷
´øÇ¿ÖƵ¼Ïò´¥µãµÄ°²È«¼ÌµçÆ÷
PCB¼ÌµçÆ÷
΢Ðͼ̵çÆ÷
Ë«ÎÈ̬¼ÌµçÆ÷
Íâ¿Ç
¿ª¹Ø¹ñÍâ¿Ç
ÅäµçÏäÍâ¿Ç
In-Rail-Bus
×Ô¶¯»¯²úÆ·
Dold ÊÇÅ·ÖÞ¹¦Äܰ²È«¡¢µçÆø°²È«¡¢ÖÇÄÜÇý¶¯¼¼ÊõÒÔ¼°µç×ÓÍâ¿ÇºÍ°²È«¼ÌµçÆ÷ÁìÓòµÄÐÐÒµ´ú±íÖ®Ò»¡£Dold ÌṩÒÔÏÂÁìÓòµÄ×Ô¶¯»¯½â¾ö·½°¸......
Á˽â¸ü¶à
ÐÐÒµ·ÖÀà
¹¤³§×Ô¶¯»¯
ʳƷºÍÒûÁÏÐÐÒµ
ľ¹¤ÐÐÒµ
»úеºÍ¹¤³§¹¤³Ì
Æû³µÐÐÒµ
Ó¡Ë¢ºÍÔìÖ½ÐÐÒµ
°ü×°ÐÐÒµ
»ú´²
ÎïÁ÷×Ô¶¯»¯
Ìú·ÐÐÒµ
Çý¶¯ºÍÊäËͼ¼Êõ
Ôì´¬¡¢¸Û¿ÚºÍÔì´¬³§
»ú³¡
½»Í¨
½»Í¨
½¨Öþ×Ô¶¯»¯
µçÌݺÍ×Ô¶¯·öÌÝ
ÄÚ²¿ÎïÁ÷
¹ý³Ì×Ô¶¯»¯
»ØÊÕÐÐÒµ
Ô²ÄÁϼӹ¤
¸ÖÌúºÍ½ðÊôÐÐÒµ
»¯Ñ§ºÍʯ»¯ÐÐÒµ
ʯÓͺÍÌìÈ»ÆøÐÐÒµ
ÆäËûÓ¦ÓÃÁìÓò
ÄÜÔ´¼¼Êõ
¿ÉÔÙÉúÄÜÔ´
Ò½ÁƼ¼Êõ
Êý¾ÝÖÐÐĺÍÐÅÏ¢¼¼Êõ
¶¯ÎïÔ°ºÍ¶¯ÎïΧÀ¸
ÒÆ¶¯µçÔ´
·ÏË®´¦Àí¼¼Êõ
µç¶¯³öÐÐ
ÐÐÒµ
×÷Ϊ¹¦Äܰ²È«¡¢µçÆø°²È«ºÍÇý¶¯¼¼ÊõÁìÓòµÄÓÐÁ¦ºÏ×÷»ï°é£¬ÎÒÃÇ»¹ÎªÄúÌṩÐÐÒµÄڵĽâ¾ö·½°¸¡£³ýÁ˱ê×¼½â¾ö·½°¸Ö®Í⣬ÎÒÃÇʼÖÕÊÇÄúºÏÊʵĺÏ×÷»ï°é...
Á˽â¸ü¶à
½øÈëÓ¦ÓÃÁìÓòÀà±ð
²âÁ¿Óë¼à¿Ø
ÈíÆô¶¯ÓëÖÆ¶¯
°²È«·À»¤
¾²Ö¹ÓëËٶȼà²â
Çл»Óë¿ØÖÆ
Ó¦ÓÃÁìÓò
´Óµ¥¹¦Äܰ²È«¿ª¹ØÉ豸µ½¶à¹¦Äܰ²È«ÏµÍ³£¬DOLD ΪÄúµÄÓ¦Óÿª·¢½â¾ö·½°¸¡£
Á˽â¸ü¶à
½øÈ빫˾Àà±ð
¹ØÓÚ¶àµÂ
¹ØÓÚÎÒÃÇ
¹«Ë¾½éÉÜ
ÎÒÃǵľÑé¡£ÄúµÄ°²È«¡£ DOLDÊÇÒ»¼ÒÃæÏò¹ú¼ÊµÄÖÐÐͼÒ×åÆóÒµ¡£ËüΪȫÇò°²È«×Ô¶¯»¯¿ª·¢¡¢ÖÆÔìºÍÏúÊÛ¸ßÆ·ÖÊ×é¼þºÍÍêÕû½â¾ö·½°¸...
Á˽â¸ü¶à
¤k
¤i
λÖÃ:
²úÆ·
´øÖƶ¯¹¦ÄܵÄÈíÆô¶¯Æ÷
´øÖƶ¯¹¦ÄܵÄÈíÆô¶¯Æ÷
¿í¶È£º112.5 mm
¸ºÔصçѹ¿É´ï£º3AC 480 V
ÊÊÓÃÓÚÈýÏàµç¶¯»ú£¬400 Vʱ¹¦Âʿɴ15 kW
±àÂë:
ÐͺÅ:
BL 9028
²ÎÊýÓÅÊÆ
ÏÂÔØ
ÌØÕ÷
²ÎÊý
¿í¶È£º112.5 mm ¸ºÔصçѹ¿É´ï£º3AC 480 V ÊÊÓÃÓÚÈýÏàµç¶¯»ú£¬400 Vʱ¹¦Âʿɴ15 kW...
more
Close menu
²ÎÊý
Widths:
112,5 mm
Load voltage up to:
3AC 480 V
For three-phase motors, 400 V up to:
15 kW
Auxiliary voltage required:
Yes
Signalling output:
Yes
Extra functions:
Temperature monitoring, Mains monitoring
Type:
BL 9028
ÓÅÊÆ
ÏÂÔØ
´øÖƶ¯¹¦ÄܵÄÈíÆô¶¯Æ÷˵Ã÷Êé (PDF)
ÌØÕ÷
According to IEC/EN 60947-4-2
2-phase motor control
For motors up to 11 kW at 3 AC 400 V
Separate settings for start and brake time, as well as
starting and braking torque
No braking contactor necessary
Function test of brake circuit before softstart
With automatic standstill detection
Current monitoring
- to protect the power semiconductors
- for device protection at stalled motor
Maintenance- and wearfree
Auxiliary DC 24 V
Monitors undervoltage and phase sequence
With input to detect motor temperature via PTC (variant /_1_)
3 relay outputs for indicaiton of status and fault with LED-indication
Width: 112.5 mm
°æÈ¨ËùÓÐ ¶àµÂµçÆø£¨Ì«²Ö£©ÓÐÏÞ¹«Ë¾ ËÕICP±¸2022047536ºÅ | ËÕ¹«Íø°²±¸32058502011749ºÅ