²Ëµ¥
ËÑË÷
Search
·þÎñÇøÓò
¹Ø±Õ²Ëµ¥
·þÎñÇøÓò
怫
²úÆ·
ÐÐÒµ
Ó¦ÓÃÁìÓò
¹ØÓÚÎÒÃÇ
·ÖÀà²úÆ·
²úÆ·²éѯ
¼ÌµçÆ÷Ä£¿é
°²È«¼¼Êõ
¼à¿ØÄ£¿é
µçÁ¦µç×Ó
¿ØÖÆÉ豸
¶¨Ê±Æ÷
°²×°µç×ÓÉ豸
°²È«¿ª¹Ø£¬·À»¤Ëø£¬Ô¿³×½»»»
°²È«¿ª¹Ø
·À»¤Ëø
Ô¿³×½»»»
µ¥¸öÄ£¿é
Ö¸ÁîÉ豸
´øÁªËøµÄ¸ºÔظôÀëÆ÷
PCB ¼ÌµçÆ÷
´øÇ¿ÖƵ¼Ïò´¥µãµÄ°²È«¼ÌµçÆ÷
PCB¼ÌµçÆ÷
΢Ðͼ̵çÆ÷
Ë«ÎÈ̬¼ÌµçÆ÷
Íâ¿Ç
¿ª¹Ø¹ñÍâ¿Ç
ÅäµçÏäÍâ¿Ç
In-Rail-Bus
×Ô¶¯»¯²úÆ·
Dold ÊÇÅ·ÖÞ¹¦Äܰ²È«¡¢µçÆø°²È«¡¢ÖÇÄÜÇý¶¯¼¼ÊõÒÔ¼°µç×ÓÍâ¿ÇºÍ°²È«¼ÌµçÆ÷ÁìÓòµÄÐÐÒµ´ú±íÖ®Ò»¡£Dold ÌṩÒÔÏÂÁìÓòµÄ×Ô¶¯»¯½â¾ö·½°¸......
Á˽â¸ü¶à
ÐÐÒµ·ÖÀà
¹¤³§×Ô¶¯»¯
ʳƷºÍÒûÁÏÐÐÒµ
ľ¹¤ÐÐÒµ
»úеºÍ¹¤³§¹¤³Ì
Æû³µÐÐÒµ
Ó¡Ë¢ºÍÔìÖ½ÐÐÒµ
°ü×°ÐÐÒµ
»ú´²
ÎïÁ÷×Ô¶¯»¯
Ìú·ÐÐÒµ
Çý¶¯ºÍÊäËͼ¼Êõ
Ôì´¬¡¢¸Û¿ÚºÍÔì´¬³§
»ú³¡
½»Í¨
½»Í¨
½¨Öþ×Ô¶¯»¯
µçÌݺÍ×Ô¶¯·öÌÝ
ÄÚ²¿ÎïÁ÷
¹ý³Ì×Ô¶¯»¯
»ØÊÕÐÐÒµ
Ô²ÄÁϼӹ¤
¸ÖÌúºÍ½ðÊôÐÐÒµ
»¯Ñ§ºÍʯ»¯ÐÐÒµ
ʯÓͺÍÌìÈ»ÆøÐÐÒµ
ÆäËûÓ¦ÓÃÁìÓò
ÄÜÔ´¼¼Êõ
¿ÉÔÙÉúÄÜÔ´
Ò½ÁƼ¼Êõ
Êý¾ÝÖÐÐĺÍÐÅÏ¢¼¼Êõ
¶¯ÎïÔ°ºÍ¶¯ÎïΧÀ¸
ÒÆ¶¯µçÔ´
·ÏË®´¦Àí¼¼Êõ
µç¶¯³öÐÐ
ÐÐÒµ
×÷Ϊ¹¦Äܰ²È«¡¢µçÆø°²È«ºÍÇý¶¯¼¼ÊõÁìÓòµÄÓÐÁ¦ºÏ×÷»ï°é£¬ÎÒÃÇ»¹ÎªÄúÌṩÐÐÒµÄڵĽâ¾ö·½°¸¡£³ýÁ˱ê×¼½â¾ö·½°¸Ö®Í⣬ÎÒÃÇʼÖÕÊÇÄúºÏÊʵĺÏ×÷»ï°é...
Á˽â¸ü¶à
½øÈëÓ¦ÓÃÁìÓòÀà±ð
²âÁ¿Óë¼à¿Ø
ÈíÆô¶¯ÓëÖÆ¶¯
°²È«·À»¤
¾²Ö¹ÓëËٶȼà²â
Çл»Óë¿ØÖÆ
Ó¦ÓÃÁìÓò
´Óµ¥¹¦Äܰ²È«¿ª¹ØÉ豸µ½¶à¹¦Äܰ²È«ÏµÍ³£¬DOLD ΪÄúµÄÓ¦Óÿª·¢½â¾ö·½°¸¡£
Á˽â¸ü¶à
½øÈ빫˾Àà±ð
¹ØÓÚ¶àµÂ
¹ØÓÚÎÒÃÇ
¹«Ë¾½éÉÜ
ÎÒÃǵľÑé¡£ÄúµÄ°²È«¡£ DOLDÊÇÒ»¼ÒÃæÏò¹ú¼ÊµÄÖÐÐͼÒ×åÆóÒµ¡£ËüΪȫÇò°²È«×Ô¶¯»¯¿ª·¢¡¢ÖÆÔìºÍÏúÊÛ¸ßÆ·ÖÊ×é¼þºÍÍêÕû½â¾ö·½°¸...
Á˽â¸ü¶à
¤k
¤i
λÖÃ:
²úÆ·
´ø·´Ïò¹¦ÄܵÄÈíÆô¶¯ / ÈíÍ£Ö¹
´ø·´Ïò¹¦ÄܵÄÈíÆô¶¯ / ÈíÍ£Ö¹
¿í¶È£º72 mm
¸ºÔصçѹ¿É´ï£º3AC 400 V
ÊÊÓÃÓÚÈýÏàµç¶¯»ú£¬400 Vʱ¹¦Âʿɴ0.75 kW
±àÂë:
ÐͺÅ:
RP 9210/300
²ÎÊýÓÅÊÆ
ÏÂÔØ
ÌØÕ÷
²ÎÊý
¿í¶È£º72 mm ¸ºÔصçѹ¿É´ï£º3AC 400 V ÊÊÓÃÓÚÈýÏàµç¶¯»ú£¬400 Vʱ¹¦Âʿɴ0.75 kW...
more
Close menu
²ÎÊý
Widths:
72 mm
Load voltage up to:
3AC 400 V
For three-phase motors, 400 V up to:
0,75 kW
Auxiliary voltage required:
Yes
Signalling output:
Yes
Extra functions:
Temperature monitoring
Type:
RP 9210/300
ÓÅÊÆ
3 functions in one unit
Easy setup
No EMC-filter necessary
ÏÂÔØ
´ø·´Ïò¹¦ÄܵÄÈíÆô¶¯ / Èíֹͣ˵Ã÷Êé (PDF)
ÌØÕ÷
According to EN 60947-4-2
For controlling of 3-phase motors up to 750 W
With 2-phase softstart and softstop
Temperature monitoring of the motors with PTC or thermal switch
3 potentiometer for adjustment of softstart, softstop and starting - deceleration time
3 LED-indicators
Reversing with relays, softstart and softstop with thyristors
2 x 24 V-inputs for clockwise rotation, anticlockwise rotation
Short circuit proof for 24 V monitoring output
Galvanic separation of control circuit and power circuit
Width 72 mm